  • Longitudinal Seismic Bracing for Cable Trays in Myanmar

    Longitudinal Seismic Bracing for Cable Trays in Myanmar

    This study aims to develop a simple yet efficient performance-based design optimization methodology for cable tray systems in building structures. In the paper, the drift ratio between adjacent supports i.

    [PDF Version]
  • New Telecom Site Power Supply System for Oil Pipeline Monitoring

    New Telecom Site Power Supply System for Oil Pipeline Monitoring

    This paper proposes an off-grid power supply system comprised of a reversible solid oxide fuel cell (RESOC), photovoltaic (PV) and battery. Minimum operating costs and the reliability of system operations under constraint conditions are the key determining objectives. ABB is a leading supplier of complete telecommunication solutions to the oil and gas industry, with unique capabilities for large offshore, onshore and pipeline communication projects. Customized telecommunication solutions for reliable and flexible communications throughout and around the. An oil and gas pipeline monitoring platform uses internet of things (IoT) to ensure safe operation in remote and unattended areas, through automatic monitoring and systematic control on equipment such as the cut-off valves and cathodic protection systems. With the growing need for more efficient, safe, and sustainable pipeline operations, traditional monitoring methods are increasingly inadequate to address. Reporting Tools: Generating reports on system performance and maintenance activities.

    [PDF Version]
  • New Zealand Vertical Distribution Box Explosion-proof Specifications

    New Zealand Vertical Distribution Box Explosion-proof Specifications

    The explosion proof enclosure range has Atex, IECEx, UL Certification s suitable for Zone 1, 2, 21 and 22 Hazardous Areas applications. The highlights: Up to four control elements can be mounted under a single actuator. • Voltmeters and ammeters withstand ambient temperatures as. The Building Product Specifications First Edition was issued 28 July 2025 under section 25B(1) of the Building Act 2004. Using products that comply with the Building Product Specifications can support demonstrating compliance with one or more parts of the Building Code through the use of acceptable. The BXM (D)58 series explosion-proof distribution box is designed for safe and reliable power and lighting distribution in hazardous areas. It is widely used in industries such as oil & gas, chemical plants, offshore platforms, and dust hazardous environments. New GIB® Fire Rated Systems Manual now available. For outdoor use, rainproof cover or protective cabinet can b added. Ex e rated, explosion protected, fixed lid pushbutton.

    [PDF Version]
  • Papua New Guinea Customized LPO Optical Module 800G

    Papua New Guinea Customized LPO Optical Module 800G

    Designed for AI/ML applications, this advanced 800G DR8 OSFP finned top LPO module enables high-speed data transmission with ultra-low power consumption, reduced latency, and superior cost efficiency. New Castle, Delaware – FS, a trusted provider of ICT products and solutions, has launched its cutting-edge 800G Linear Pluggable Optics (LPO) module. These products are engineered for ultra-low power consumption and high-density AI clusters, significantly reducing the operational overhead of. The 800G LPO QSFP-DD800 optical transceiver provides an optimized solution for next-generation networks, delivering ultra-low latency, exceptional energy efficiency, and reliable high-bandwidth connectivity. The FS 800G LPO DR8 module. Why is 800G more significant than 400G for AI servers? In recent years, with the emergence of new businesses such as VR, IoT, and cloud computing, the market has higher requirements for network bandwidth, concurrency, and real-time performance. With the continuous increase in bandwidth demand. FS, Inc.

    [PDF Version]
  • BYD New Energy Distribution Box

    BYD New Energy Distribution Box

    BYD has officially launched its first fully integrated high-voltage residential energy storage system – the Battery-Box HVE, paired with the new Power-Box hybrid inverter series. BYD's generation/grid-side energy storage solutions deliver all-value applications for global power systems which not only elevates the dynamic response capability and system inertia of large-scale new energy bases, but also improves grid robustness and enhances transmission grid resilience. One Battery-Box Premium HVS is composed of 2 to 5 HVS battery modules that are connected in series to achieve a usable capacity of 5. Ability to scale by adding. Shenzhen/Munich, Dec 18, 2025 – BYD Energy Storage, a business division of BYD Co. 6/5/6K or the three-phase hybrid inverter.

    [PDF Version]
  • New Calculator for Cable Tray Elbows

    New Calculator for Cable Tray Elbows

    The Cable Tray Sizing Calculator is an electrical calculator tool designed to determine the correct cable tray dimensions for electrical installations. Accurate fill ratio analysis and tray sizing per NEC, IEC 60364, and BS 7671 standards. Enter your cable schedule below to get started. Click here. The right cable tray sizing calculator helps engineers turn cable schedules into a verified tray width and fill check before material ordering and site installation. IEC 61537 covers cable tray and cable ladder systems for the support and accommodation of cables, while NEC Article 392 governs cable. The International Electrotechnical Commission (IEC) outlines clear guidelines in IEC 61537 for determining the appropriate tray or ladder based on mechanical strength, ventilation, electrical continuity, and fill capacity. Select Fill Standard: Choose 40% for power cables (NEC compliant) or 50% for.

    [PDF Version]
  • Selection Guide for New QSFP Optical Modules for Oil and Petrochemical Applications

    Selection Guide for New QSFP Optical Modules for Oil and Petrochemical Applications

    A practical, engineer-friendly guide to choosing the right transceiver form factor by speed, port density, power, migration plan, and operational risk—built for 25G/100G networks in 2026. 25G SFP28 is the new access/server baseline; deploy it for port density and long-term. QSFP (Quad Small Form-Factor Pluggable) optical modules emerged to meet this demand, becoming a pivotal technology for data center interconnects due to their compact size and exceptional performance. From the initial 40G to today's 800G, the QSFP family has continuously evolved, driving the. While 100G remains the workhorse for enterprise edges, the core data center has rapidly migrated to 400G (QSFP-DD) and is actively piloting 800G deployments. These hot-pluggable transceivers provide high-density, high-performance connectivity.

    [PDF Version]
  • Secondary status inspection of relay protection

    Secondary status inspection of relay protection

    Secondary injection checks the operation of the protective system but does not check the primary circuit of the current transformer. The new generation of intelligent substations has achieved online monitoring functions for secondary equipment, making some state variables of relay protection equipment become observable indicators. These are not repeated unless incorrect operation occurs. Most frequently they are performed by simulating test conditions by means of portable test sets. Other methods include : tests using. This guide explores the different types of protection relays and their testing procedures, with a focus on tools like secondary injection test sets and three-phase relay test sets. For over 50 years, Electrical Reliability Services (ERS) has been providing startup.

    [PDF Version]
  • Relay Protection Inspection Procedures

    Relay Protection Inspection Procedures

    During visual inspection, the relay should be checked for any signs of damage, such as physical wear and tear, loose connections, or corrosion. These devices spend years in standby mode, waiting to isolate faults in milliseconds when called upon. Yet without structured, documented maintenance, organizations often discover relay. The testing and verification of relay protection devices can be divided into four groups: Type tests are needed to prove that a protection relay meets the claimed specification and follows all relevant standards. Since the basic function of a protection relay is to correctly function under abnormal. Protective circuit functional testing, including lockout relay testing, must take place immediately upon installation, every 2 years thereafter, and upon any change in wiring. Acceptance tests fall into two categories : (i) On new relays which are to be used for the first time. Applications: Overcurrent. THEY SHOULD BE GIVEN FIRST LINE MAINTENANCE ATTENTION. ” relay may only need to operate for 0.

    [PDF Version]
  • Principle of Automatic Visual Inspection of Fiber Optic Patch Cords

    Principle of Automatic Visual Inspection of Fiber Optic Patch Cords

    Endface inspection focuses on the visible quality of the polished fiber surface and surrounding ferrule area. You use a fiber microscope or automated inspection scope to check for contamination, pits, chips, cracks, and scratches. Even a small dust particle or scratch on the endface can increase insertion loss, reduce return loss, and introduce random link instability. The primary reason for fiber inspection is to ensure that the connectors are free of any defects, damage, or debris that would prevent sufficient transmission of light when mated. Normal Inspection Items for Fiber Optic Patch Cords Fiber optic patch cords are critical components in communication systems, connecting various devices and ensuring efficient data transmission. To maintain high-quality performance, a thorough inspection process is essential. The. FOCIS WiFi2 is an ergonomic Fiber Optic Connector Inspection System that, when paired with an iOS or Android smart device, provides fast and accurate IEC/IPC/AT&T compliant and user-defined pass/fail end-face cleanliness analysis. FOCIS Duel is a self-contained twin-ported Bluetooth connected fiber.

    [PDF Version]
  • Fiber Optic Cable Sheath Inspection Section

    Fiber Optic Cable Sheath Inspection Section

    The procedures in this document describe basic inspection techniques and processes of cleaning for fiber optic cables, bulkheads, and adapters used in fiber optic connections. These types are (Figure 1): Type A 1) The sheath is peeled or chipped. 2) No portion of the armor or cable core is exposed. After cable placement is complete the residual tension on the cable should be less than this value. NOTE: Steps that reference. There are three main principles that needs to be taken in consideration for an efficient optical connection: a perfect core alignment, perfect physical contact and dirt-free connectors.

    [PDF Version]
  • How to weld a 4-core optical fiber cable

    How to weld a 4-core optical fiber cable

    The thermal welding method involves the use of a special welding machine that produces an electric arc that melts the ends of the optical fibers, connecting them together. Fiber Optic Welding How To Joint Fiber Optic Cablesplicing fiber optic cable,fiber optic splice,fiber optic,fiber optics,fiber splice,how to splice,fibre opt. The welded ends are then pressed and a weld is formed. Procedure for welding optical cables 1. Basic. A qualified fiber end face is a necessary condition for welding, and the end surface quality affects the quality of the welding. "Flat" means to keep the fiber flat. Isopropyl alcohol and lint-free wipes are.