Product Guide Red615 Line
  • Types of Line Relay Protection

    Types of Line Relay Protection

    In radial feeder, the power flows in one direction only, which is from source to load. This type of feeders can easily be protected by using either definite time relays or inverse time relays.

    [PDF Version]
  • What are the differential current protection methods for relay protection

    What are the differential current protection methods for relay protection

    The differential protection scheme utilizes current transformers (CTs) placed at both ends of the protected zone to measure the incoming and outgoing currents. These CTs feed the measured current values to a differential relay. In each case, the measurement is based on Kirchhoff's laws which state that the geometric (vector) sum of the. What controls it: CT location, CT polarity, CT ratio, transformer compensation, restraint logic, and relay settings control performance.

    [PDF Version]
  • Distance between fire protection cable trays

    Distance between fire protection cable trays

    This design note adopts a 300 mm horizontal air-gap separation between primary and secondary life-safety trays on roofs, based on these regulatory requirements and established UK guidance. However, BS 7671, BS 8519, and BS 5839 collectively establish that. Although BS 7671 touches on the subject of cable supports, it does not detail specifically what these support distances should be. Clause 522-08-04 Where conductors or cables are not supported. The distance between trays affects not only the ease of maintenance but also cable protection, heat dissipation, and system stability. This document outlines the key requirements for cable tray layout, installation, and fireproofing in industrial and commercial environments. Where cables pass through shafts, walls, slabs, or enter electrical panels or cabinets, openings shall be tightly sealed with firestopping materials in accordance with. In passive fire protection (PFP), separation distance is the minimum space required between services (e. It's not a generic rule of thumb; it's the dimension proven in a test or technical assessment for a.

    [PDF Version]
  • The function of the integrated wiring cabinet in the relay protection room

    The function of the integrated wiring cabinet in the relay protection room

    These are used to house a combination of 19” modular chassis, protection relays, switches, auxiliary relays, terminals, wiring and trunking. Protective relays and devices have been developed over 100 years ago to provide “lastline”of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. Definite time delay means that the protection operate time dose not change or depend on the. presentation of protection and control relaying. Fundamental concepts and terminology will be taught using the electromechanical overcurrent relay as a foundation. The specification relates to the Onshore Compensation Compound (OCC) and Offshore Substation Platform (OSP).

    [PDF Version]